Table 102 Using a Delta Resync Configuration (continued)

See

Description

Target

Maintenance or
Failure

No.

Operation in a delta
resync configuration is
not affected.

Local site host
maintenance

5

Operation in a delta
resync configuration is
not affected.

Remote site host
maintenance

6

“Operating Procedure
During a Primary Site

Perform a delta
resync, and then

Primary site storage
system (volatile)

Failure

7

Storage System Failure
(Volatile)” (page 404)

change the
configuration to a
2DC configuration
(Local

→ Remote).

During failback, Cnt
Ac-S Z copy pairs and
Cnt Ac-J Z copy pairs
must be deleted and
then recreated.

“Operating Procedure
During a Primary Site

Perform a delta
resync, and then

Primary site storage
system failure
(nonvolatile)

8

Storage System Failure

change the

(Nonvolatile)”
(page 410)

configuration to a
2DC configuration
(Local

→ Remote).

“Operating Procedure
During a Local Site

Suspend Cnt Ac-S Z
copy pairs, and then

Local site storage
system failure (volatile)

9

Storage System Failure
(Volatile)” (page 414)

change the
configuration to a
2DC configuration
(Primary

→ Remote).

During recovery, the
Cnt Ac-S Z copy pairs
and delta resync pairs
must be deleted and
then recreated.

“Operating Procedure
During a Local Site

Suspend Cnt Ac-S Z
copy pairs, and then

Local site storage
system failure
(nonvolatile)

10

Storage System Failure

change the

(Nonvolatile)”
(page 418)

configuration to a
2DC configuration
(Primary

→ Remote).

“Operating Procedure
During a Remote Site

After error recovery,
the Cnt Ac-J Z copy

Remote site storage
system failure (volatile)

11

Storage System Failure
(Volatile)” (page 418)

pairs and delta resync
pairs must be deleted
and recreated.

“Operating Procedure
During a Remote Site

After error recovery,
resynchronize Cnt Ac-J
Z copy pairs.

Remote site storage
system failure
(nonvolatile)

12

Storage System Failure
(Nonvolatile)”
(page 421)

388 Maintenance and troubleshooting operations