beautypg.com

Design center, Stage 4 (sew setting stage) – Brother PE-DESIGN Ver.6 User Manual

Page 100

background image

92

Design Center

Stage 4 (Sew Setting Stage)

Fill stitch

Running Stitch Path

Sets the running path of the stitching.
Available when the type of sewing direction is set to Constant.
Available settings:
• Inside of region (shortest route)
• Along outline (along the inner side)
• Onto outline (on the outline)
The inside of region setting is available only when the Gradation
check box is cleared.
Default: Inside of region

Pull Compensation

Lengthens the sewing region in the stitch pattern’s sewing direction to prevent pattern shrink-
age during sewing.
Range: 0–2 mm (0.00–0.08 inch)
Default: 0.0 mm (0.00 inch)

Inside of region:

Along outline:

Onto outline:

Under sewing

Sets underlay stitching on or off. Try to use underlay stitching for wide areas, in order to pre-
vent shrinking during stitching. Depending on the shape of the region, however, it may not be
possible to select this setting.
On: Underlay stitching will be sewn.
Off: Underlay stitching will not be sewn.

Density

Sets the number of lines per millimeter.
Range: 1–7 lines per mm (25–178 lines per inch)
Default: 4.5 lines per mm (114 lines per inch)

Gradation

Sets the density gradation setting on or off.
Available when the type of sewing direction is set to Constant.
Click Pattern to set the gradation pattern and its density.
Default: Off
For details on this attribute, refer to“Creating a gradation” on page 96.

Direction

[Type] Specifies the type of sewing direction.
Constant: Sews at a fixed angle. The angle is specified by the angle setting.
Variable: Varies the sewing direction according to the object being sewn.
[Angle] Specifies the sewing angle.
Available only when the sewing direction type is
set to Constant.
Range: 0–359 degrees
Default: 45 degrees

Stitch Type

Specifies the shape of stitching on the edges.

Available settings:

,

Default:

Half Stitch

Sets half stitching on or off.
Available when the type of sewing direction is set to Vari-
able
.
If one side of the fill stitching is dense, a half stitch could be
sewn automatically to provide a more even density.
Default: Off

Running Stitch Path

Sets the running path of the stitching.
Available when the type of sewing direction is set to Constant.
Available settings:
• Inside of region (shortest route)
• Along outline (along the inner side)
• Onto outline (on the outline)
The inside of region setting is available only when the Gradation
check box is cleared.
Default: Inside of region

Step Pitch

Sets the pitch of the stitching.
Range: 1–10 mm (0.04–0.39 inch)
Default: 4.0 mm (0.16 inch)

45°

90°

135°

180°

225°

270°

315°

On:

Off:

Inside of region:

Along outline:

Onto outline:

Step pitch

PeDesignV6Eng.book Page 92 Thursday, July 8, 2004 11:59 AM