beautypg.com

Electrical connections – KROHNE MFC 400 EN User Manual

Page 43

background image

ELECTRICAL CONNECTIONS

4

43

MFC 400

www.krohne.com

08/2013 - 4002075802 - MA MFC 400 R02 en

4.10.4 Modular inputs/outputs and bus systems

Current output active (only current output terminals C/C- have HART

®

capability),

modular I/Os

• U

int, nom

= 24 VDC

• I ≤ 22 mA
• R

L

≤ 1 kΩ

• X designates the connection terminals A, B or C, depending on the version of the signal

converter.

Current output passive (only current output terminals C/C- have HART

®

capability),

modular I/Os

• U

ext

≤ 32 VDC

• I ≤ 22 mA
• U

0

≥ 1.8 V

• R

L

≤ (U

ext

- U

0

) / I

max

• X designates the connection terminals A, B or C, depending on the version of the signal

converter.

CAUTION!
Observe connection polarity.

INFORMATION!

For further information on electrical connection refer to Description of the inputs and outputs
on page 38.

For the electrical connection of bus systems, please refer to the separate documentation for
the respective bus systems.

Figure 4-11: Current output active I

a

Figure 4-12: Current output passive I

p

.book Page 43 Monday, August 26, 2013 9:05 AM