ELECTRICAL CONNECTIONS

4

23

MFC 400

www.krohne.com

08/2013 - 4002075802 - MA MFC 400 R02 en

4.4.1 Connection of signal cable - Field housing and connection box for sensor

1 Unscrew the terminal compartment cover.
2 Pass the prepared signal cable through the cable entry.
3 Secure the signal cable using the clip.
4 Connect the electrical conductors as shown. The shielding must also be connected to the

spring terminal.

5 Re-fit the cover and tighten it by hand.

Figure 4-1: Connection of signal cable - Field housing and connection box for sensor

Cable

Cable

Connection terminal

Cable pair

Colour

1

yellow

X1 SA+

1

black

X1 SA-

2

green

X1 SB+

2

black

X1 SB-

3

blue

X2 T1

3

black

X2 T2

4

red

X2 T3

4

black

X2 T4

5

white

X3 DR+

5

black

X3 DR-

INFORMATION!
Each time a housing cover is opened, the thread should be cleaned and greased. Use only resin-
free and acid-free grease.
Ensure that the housing gasket is properly fitted, clean and undamaged.

.book Page 23 Monday, August 26, 2013 9:05 AM