beautypg.com

Technical data – KROHNE MFC 400 EN User Manual

Page 125

background image

TECHNICAL DATA

8

125

MFC 400

www.krohne.com

08/2013 - 4002075802 - MA MFC 400 R02 en

Materials

Signal converter housing

Standard: die-cast aluminium (polyurethane coated)

Option: stainless steel 316 (1.4408)

Measuring sensor

For housing material, process connections, measuring tubes, accessories and

gaskets, refer to technical data for the measuring sensor.

Electrical connection

General

Electrical connection is carried out in conformity with the VDE 0100 directive

"Regulations for electrical power installations with line voltages up to 1000 V" or

equivalent national specifications.

Power supply

Standard: 100…230 VAC (-15% / +10%), 50/60 Hz

Option 1: 24 VDC (-55% / +30%)

Option 2: 24 VAC/DC (AC: -15% / +10%, 50/60 Hz; DC: -25% / +30%)

Power consumption

AC: 22 VA

DC: 12 W

Signal cable

Only for remote versions.

10 core shielded cable. Detailed specifications are available on request.

Length: max. 20 m / 65.6 ft

Cable entries

Standard: M20 x 1.5 (8...12 mm)

Option: ½ NPT, PF ½

.book Page 125 Monday, August 26, 2013 9:05 AM