Technical data, 2 technical data – KROHNE MFC 400 EN User Manual
Page 122
8
TECHNICAL DATA
122
MFC 400
www.krohne.com
08/2013 - 4002075802 - MA MFC 400 R02 en
8.2 Technical data
INFORMATION!
•
The following data is provided for general applications. If you require data that is more
relevant to your specific application, please contact us or your local sales office.
•
Additional information (certificates, special tools, software,...) and complete product
documentation can be downloaded free of charge from the website (Download Center).
Measuring system
Measuring principle
Coriolis principle
Application range
Measurement of mass flow, density, temperature, volume flow, flow velocity,
concentration
Design
Modular construction
The measuring system consists of a measuring sensor and a signal converter.
Measuring sensor
Measuring sensor
Measuring sensor
Measuring sensor
OPTIMASS 6000
DN08…250 / 3/8...10"
All measuring sensors are also available in an Ex version.
Signal converter
Signal converter
Signal converter
Signal converter
Compact version (C)
OPTIMASS 6400 C
Field housing (F) -
remote version
MFC 400 F
Compact and field housing versions are also available as Ex versions.
Options
Options
Options
Options
Outputs / inputs
Current output (incl. HART
®
), pulse output, frequency output, and/or status output,
limit switch and/or control input (depending on the I/O version)
Totaliser
2 (optional 3) internal totalisers with a max. of 8 counter places (e.g. for counting
volume and/or mass units)
Verification
Integrated verification, diagnostic functions: measuring device, process, measured
value, stabilisation
Concentration measurement
Concentration and concentration flow
Communication interfaces
Foundation Fieldbus, Profibus PA and DP, Modbus, HART
®
.book Page 122 Monday, August 26, 2013 9:05 AM