beautypg.com

In-Situ TROLL 9500 Operators Manual User Manual

Page 4

background image

0095110 rev. 007 01/09

TROLL 9500 Operator’s Manual

CONTENTS

IV

Customizing the Profiler .................................................................... 34

Changing the Channels Displayed .................................. 34
Changing Measurement Units ........................................ 34
Changing the Sample Rate ............................................. 34
Starting in Profiler Mode .................................................. 34

Logging Profiler Data ........................................................................ 34

To Stop Logging ...................................................................... 34
Retrieving Logged Profiler Data ............................................... 34

Exiting the Profiler ............................................................................. 34

6 LOGGING DATA .............................................. 35

Adding a Test to a Device: The Test Wizard ..................................... 35

Test Setup Parameters............................................................. 36

1. Test Name (Optional) .................................................. 36
2. Parameters to Include ................................................. 36
3. Measurement Schedule ............................................. 36
4. Measurement Interval ................................................. 37
5. Start Mode ................................................................... 37

Ending Setup ........................................................................... 37

More on Measurement Schedules .................................................... 37

Linear ...................................................................................... 37
Event ....................................................................................... 37
Linear Average ......................................................................... 38

Other Test Operations ....................................................................... 39

Starting a Manual Start Test ..................................................... 40
Stopping a Test ........................................................................ 40
Retrieving Logged Data ........................................................... 40
Deleting Tests ........................................................................... 41
Cloning a Test .......................................................................... 41

Transferring Files from a PDA to a Desktop PC ............................... 42
Viewing Logged Data ........................................................................ 43

Selecting Data in the Data Folder ............................................ 43

Graphing Data .................................................................................. 44
Changing the Data Display ............................................................... 45
Transferring Data to Excel from Win-Situ 4 ...................................... 45
Printing Data in Win-Situ 4 ................................................................ 45
Saving Text Files from Win-Situ 4 ..................................................... 45

7 MONITORING PRESSURE (WATER LEVEL) .......... 46

Why Monitor Pressure? .................................................................... 46
The Pressure Sensor ........................................................................ 46

Factory Calibration ................................................................... 46
Operating Principle .................................................................. 47
Non-Vented (Absolute) vs. Vented (Gauged) Sensors............. 47
Pressure vs. Depth vs. Level ................................................... 47

Zeroing the Pressure Sensor ............................................................ 47
Setting up Pressure Measurements: The Parameter Wizard ........... 48

Pressure Setup Choices .......................................................... 48
1. Name (Optional) ................................................................... 48
2. Display Mode ....................................................................... 48
3. Converting Pressure to Depth or Level ................................ 49

Conversion Using Specific Gravity .................................. 49
Conversion Using Density, Latitude, and Elevation ......... 49

4. Level Reference ................................................................... 49

Reference Time ............................................................... 49

Quick Summary of Pressure Setup .................................................. 50
Installation for Pressure/Level Measurement ................................... 51

Securing the Cable .................................................................. 51
Stabilization Time ..................................................................... 51
Twist-Lock Hanger Installations ............................................... 51

Installation Tips for Level/Depth/Pressure Monitoring ..... 51

Correcting Absolute Pressure Readings for Barometric Pressure .... 52

Manual Barometric Pressure Compensation ........................... 52

Using the MP TROLL’s Barometric Pressure Sensor ...... 52
Using a Second Unit and a Spreadsheet ........................ 52

Automatic Barometric Pressure Compensation ...................... 52

Collecting Barometric Pressure Data for Reference ....... 52
Collecting PSIA Data ....................................................... 52
Using the Baro Wizard .................................................... 52

Recalibration Recommendations ...................................................... 53

8 MONITORING TEMPERATURE ........................... 54

Why Monitor Temperature? ............................................................... 54
The Temperature Sensor .................................................................. 54

Role of the Sensor in Calibration ............................................ 55

Software Functions ........................................................................... 55
References ....................................................................................... 55

9 MONITORING BAROMETRIC PRESSURE ............. 56

What is Barometric Pressure? .......................................................... 56
Why Monitor Barometric Pressure? .................................................. 56
The Barometric Pressure Sensor ..................................................... 56
Collecting Accurate Measurements without Vented Cable ............... 56

Pressure vs. Elevation ............................................................. 57

10 MONITORING WATER QUALITY: OVERVIEW ..... 58

Why Monitor Water Quality? ............................................................. 58
The Sensors ..................................................................................... 58

Basic Sensor Set ..................................................................... 58
Installing Sensors ..................................................................... 59
Removing Sensors ................................................................... 60

Calibration Overview ......................................................................... 60

Traditional Calibration .............................................................. 60
Quick Calibration ...................................................................... 61
Out of the Box .......................................................................... 61
Default Coefficients .................................................................. 61

Preparing to Calibrate ....................................................................... 61

Calibration Kits ........................................................................ 61
The Calibration Cup ................................................................. 61
Effect of Temperature on Calibration ........................................ 62
Rinsing ..................................................................................... 62
Stirring ...................................................................................... 62

Calibration Procedures ..................................................................... 62
After Calibration ................................................................................ 62

Calibration History .................................................................... 63
How Often to Calibrate ............................................................ 64
How to Check if a Sensor is Still in Calibration ........................ 64
When to Replace a Sensor ...................................................... 65

References ....................................................................................... 65

11 PH ............................................................... 66

What Is pH? ..................................................................................... 66

Why Measure pH? .................................................................. 66

The pH Sensor ................................................................................. 66
Sensor Installation ............................................................................ 67

This manual is related to the following products: