Conventional Fieldwork
69
h. According to the screen, the rod must
now move FORWARD by 0.089 feet to
be over the design point. We will
assume that this is close enough and
will store the point from this shot by
tapping the Store… button.
i. Enter the following point information:
Point Name
: 5
Description
: Staked
and tap . This will return you to the
first Stake Points screen.
5. Stake the next design point.
a. We want to stake the next design point
in the project. Make sure 3 is in the
Design Point
field and then press
Solve > . This will send you to the
second Stake Points screen.
b. The information needed to locate the
next design point is displayed. When
connected to a total station, you would
turn the total station horizontally to
115°00’00", vertically to 90°00’00" and
send the rod man out about 100 feet before continuing. Tap
the
.
Stake >
.
button to continue to the third screen.
c. Tap the Shot button and enter the following shot data:
Angle Right
: 115
Zenith
: 90
Slope
Dist: 99.8
and then tap to continue.