Spectra Precision Survey Pro v4.5 Ranger User Manual User Manual
Page 300
User’s Manual – GPS Mode
290
coordinate system and calculate the plane location of the
autonomous base.
• You are now ready to collect data, and the Stake Points
screen is opened
6. Stake out the well site.
• Choose point 1 as the design point. Tap Solve> to preview the
picture, and Stake> to start the GPS Staking screen.
• Watch the stake out graphics, and observe the azimuth and
distance display to navigate to the point. Once you reach the
point, you would put the stake out mark in the ground.
7. Occupy the as built point in static mode for the most precise
measurement.
• Make sure your settings are correct for static RTK shots. Tap
Settings and make sure Receiver Dynamics are set to Static on
Occupy
. Tap OK.
• Tap >Roving to toggle to >Occupying mode. You will be
prompted for a name and description for the as built point
name. The receiver is set to static mode and static
measurements are taken. Watch the status bar for the session
timer.
• When you are satisfied with the length of the occupation, tap
Accept to store the point. The receiver is switched back to
roving dynamics and the results are displayed. If you wish to
stake another point tap Stake Next>.
8. Occupy a pair of points with the RTK rover for total station setup.
• Go to Survey > Data Collection
• Occupy points bCHAP and b54.
• Open the inverse screen, and inverse between bChap and b54.
9. Switch to Ground Coordinates.
• Tap Control and Projection to open the Projection screen. Tap
Setup Ground Coordinates to open the Ground Coordinates
screen.