beautypg.com

Spectra Precision Survey Pro v4.5 Ranger User Manual User Manual

Page 128

background image

User’s Manual – Conventional Mode

118

Note: When using a robotic total station and Enable Automatic

Repetition is checked in the Radial SS Settings screen, only the direct
(Face 1) shots for the first set will need to be shot manually. All
remaining shots will be performed automatically.

The Shooting Sequence is where you choose to shoot all Face 2
side shots in the same order as the Face 1 shots

(B>F1>..>Fn^F1>..>Fn>B), or in reverse order

(B>F1>..>Fn^Fn>..>F1>B).

In the Surveying Settings screen, un-checking the first four
options will keep the routine from prompting you for additional

information before storing the computed side shots.

3. Enter the Number of Sets you want to

perform and tap Shoot BS to take the Face
1 shot at the backsight point. When
finished, the Results screen shown here
will be displayed and the Next(SS D) >
button will be enabled. Tap it to continue.

Note: For optimum accuracy when shooting

repetition shots, fixed prisms should be set up
over each point. Custom Smart Targets (Page

19) will also need to be created and selected for
each prism.

4. You will now start shooting each side shot in Face 1. Be sure the

description and current smart target is selected before shooting

each Face 1 shot for the first set. (These are remembered and will
automatically update for each subsequent shot.)