Spectra Precision Survey Pro v4.5 Ranger User Manual User Manual
Page 299
GPS Module
289
zone Oregon North 3601. The default geoid is Geoid99, but
you can also select Geoid03, or EGM96.
• Tap Finish to set the coordinate system. Because you selected
a new coordinate system, the Adjust with Projection wizard
will run. In our example, our imported ASCII points have
only plane locations, so no job points will be updated. Tap
Next> and you will see a message that no job points would be
changed by the adjustment. You can review the report
anyway, or just tap Apply to finish setting the coordinate
system.
4. Set the base and rover.
• Select Set New Base>, ‘connect’ to the Demo Mode base
receiver. Enter ‘new’ for the name of the base point and tap
Next> to start the survey from an autonomous position. Tap
Set to set the base and configure the base reference position
in Survey Pro.
• Tap Set Rover> to set the rover
5. Solve the mapping plane localization adjustment.
• Tap Collect Control> to open the Control Points screen.
• Occupy point 54 as control. You will then be prompted that
you have enough to solve the adjustment. It is always
recommended that you get at least one additional control
point. In this example, choose to collect more control, and
occupy CHAP as a GPS control point.
• Tap Projection and Solve Localization… to open the Solve
Localization screen. Tap Clear All, then select point 54 as the
only horizontal and vertical control point.
• Tap Solve> and view the misclosures. You could then choose
to include some of these points in the adjustment and hit
Solve> to compute new parameters. In our example,
everything is perfect, so you will tap Next> and Accept to
solve the adjustment with just one control point.
• The Adjust with Projection wizard shows us the update to the
autonomous base position. Tap Apply to update the job