Field procedure, P – set base reference position, Turn on data recording – Spectra Precision Survey Pro v4.5 Ranger User Manual User Manual
Page 281: Start recording in receiver
GPS Module
271
Field Procedure
Turn On Data Recording
1. Go to the Job > Settings screen.
2. On the Post Process card, specify a non-zero recording
interval.
Note: For simultaneous RTK and post processing data collection,
this is all you need to do. Receiver recording will be started
automatically when you configure the RTK base and rover. Data
collection sessions will be completed automatically when you occupy
an RTK point. If you wish to do post processing only data collection,
you need to complete the next step before tapping OK.
3. Create a post processing receiver profile (Page 187).
Start Recording in Receiver
1. Go to the Survey > Post Processing screen. You will be
prompted to choose a receiver from the available post
processing receivers and the Post Processing screen will open.
Note: If you are currently connected to the RTK base or rover
receiver, you will not be allowed to enter the Post Processing screen.
If you tap Post Processing when connected to the RTK base or rover,
Survey Pro will check the receiver to see if it is currently logging
data. If it is, you will be prompted if you wish to stop data logging on
this receiver. If the receiver is not logging data, you will be prompted
if you wish to clear the RTK setup so you can set this receiver as a
post processing only receiver.
2. Choose Start Static if you want to configure a receiver to
record raw data at a stationary setup. Choose Start Stop/Go if
you want to configure a receiver to do stop and go data
collection.