User’s Manual – Leveling Mode

184

Stakeout

19. Shooting a leveling stakeout point is

similar to a leveling side shot in that it

must be done before shooting a
benchmark or turning point from any

particular setup, and once complete,

you will return to the Level screen
where the next shot type is selected,

without advancing to the next setup.

Enter the point from the current job
that you want to stake in the Stk Point
field and tap Next > to take the
necessary shots in your shooting sequence, as described in
Step 7.

Since the horizontal coordinates cannot be computed from the
leveling routine, it is assumed you already know the location

of the stake point and only want to measure the elevation for

that location to compute a cut/fill value.

Adjustment

The Leveling > Adjustment screen can be used to remove the error

computed from any existing closed loop. This is a simple arithmetic
adjustment where the computed error can be either distributed

equally among each setup in the loop, or a weighted adjustment can

be distributed where setups that are farther apart will carry more of
the error adjustment than those that are closer together.
See the Reference manual for more information on performing a level
loop error adjustment.