Post processing, Video scan – Spectra Precision Survey Pro v4.5 Ranger Reference Manual User Manual
Page 207
Survey Menu – GPS Module
R-199
Post Processing
Post processing data collection involves two steps. First, you must
open a file and begin logging GPS raw data for post processing.
Second, you must measure the antenna height and enter the antenna
and station ID for each point you occupy.
Post Processing
Survey Post Processing
The Post Processing screen is used to open or close a post processing
data file, and start or stop logging GPS raw data measurements to
the file. When you tap the Post Processing menu button, you are
prompted to choose a receiver to connect to from the list of post
processing receivers you have created.
Recording Status
: displays the current state
of receiver recording.
Start Recording / Stop Recording : this button
will activate the action which is opposite to the
current Recording Status. Tap Start Recording
to open a new log file, begin logging raw GPS
measurements for post processing to the file,
and then open the Receiver Session screen
(Page R-202) where you can input the station
name and description. Tap the Stop Recording
button to close the open log file.
Note: The location of the file is usually on the receiver’s built in
memory. However, some models support collection of post processing
data to a file on the data collector. For those receivers that support it,
the location of the log file is specified on the Receiver Settings |
General screen.
Start Static
: use this setting if you want to start a log file in static
mode, where the receiver will remain over a single point for the
duration of the session.