Type of protection

Class I, Division 1, Groups A, B, C and D (Intrinsically Safe)

Class I, Division 2, Groups A, B, C and D (Nonincendive)

Class I, Zone 0, in Hazardous (Classified) Locations (Intrinsically Safe)

Class I, Zone 2, Group IIC, in Hazardous (Classified) Locations (Nonincendive)

AEx ia IIC

For all protection type,

T4: for ambient temperature: -20 to 55°C

T6: for ambient temperature: -20 to 40°C

Atmosphere pressure: 80 kPa (0.8 bar) to 110 kPa (1.1 bar)

Degree of Protection of the Enclosure: NEMA Type 4X and IP66

CSA Intrinsically safe and nonincendive approval

Applicable standard

CAN/CSA C22.2 No. 94-M1991 Special Purpose Enclosures

CAN/CSA C22.2 No. 157-92

Intrinsically Safe Equipment for Use in Hazardous Locations

C22.2 No213-M1987

Non-incendive Electrical Equipment for Use in Class I, Division 2

Hazardous

Locations

CAN/CSA-E60079-0-07

Electrical apparatus for explosive gas atmospheres

- Part 0: General requirements

CAN/CSA-E60079-11-02

Electrical apparatus for explosive gas atmospheres

- Part 11: Intrinsic safety “i”

IEC 60529:2001

Degrees of protection provided by enclosures (IP Code)

Type of protection (C22.2)

Class I, Division 1, Groups A, B, C and D (Intrinsically Safe)

Class I, Division 2, Groups A, B, C and D (Nonincendive)

For all protection type,

T4: for ambient temperature: -20 to 55°C

T6: for ambient temperature: -20 to 40°C

Atmosphere pressure: 80 kPa (0.8 bar) to 110 kPa (1.1 bar)

Ambient Humidity: 0 to 100% (No condensation)

Degree of Protection of the Enclosure: Type 4X

Type of protection (E60079)

Ex ia IIC

T4: for ambient temperature: -20 to 55°C

T6: for ambient temperature: -20 to 40°C

Atmosphere pressure: 80 kPa (0.8 bar) to 110 kPa (1.1 bar)

Ambient Humidity: 0 to 100% (No condensation)

Degree of Protection of the Enclosure: IP66

Electrical Parameters (Ex ia)

Each housing assembly (base module) and each sensor module are respectively certificated.

Input parameters of sensor module meet output parameters of housing assembly.

Housing assembly

Input parameters

Supply and output circuit (terminals + and -):

Ui, Vmax

= 30 V

Ii, Imax

= 100 mA

Pi, Pmax

= 0.75 W

Ci

=13 nF

Li

= 0 mH

(Linear source)

Output parameters

Sensor module input circuit (CN2 or CN3 on Back board)

Uo Vt, Voc

= 13.65 V

Io, It, Isc

= 50 mA

Po

= 0.372 W

Co, Ca

= 80 nF

Lo, La

= 7.7mH

This manual is related to the following products: