TROUBLE SHOOTING

Ifforanyreasonyoudonotunderstandthetestproceduresorareunabletoperformthetests/repairssafely,contactyour
Local Lincoln Authorized Field Service Facility fortechnicaltroubleshootingassistancebeforeyouproceed.

CAUTION

POWER FEED 84, POWER FEED 84 DUAL

ObserveallSafetyGuidelinesdetailedthroughoutthismanual

PROBLEMS

(SyMPTOMS)

POSSIBLE

CAUSE

RECOMMENDED

COURSE OF ACTION

Fault Code

Err 18 Configuration error

Err 81 Motor overload, long term.

Err 82 Motor overload, short term.

The feeder does not power up - no voltage,
no cold feed.

The green LED on the wire drive or user
interface is flashing quickly.

The feeder is stuck in procedure B.

Description

1. The DIP switch setting for the user inter-

face does not match the wire drives. The
UI is set for “single” with a “dual” wire
drive, or the UI is set for “dual” with a
“single” wire drive.

1. The wire drive motor has overheated.

1. The wire drive motor current draw has

exceeded limits, usually because the
motor is in a locked rotor state.

1. The work sense lead is disconnected or

is a poor electrical connection. (Across
the arc models)

2. The power source is OFF.
3. The circuit breaker for the wire feeder on

power source have tripped. (control
cable models)

4. The control cable may be loose or dam-

aged. (control cable models)

1. Loss of ArcLink communication between

the wire feeder and the power source.

2. Loss of ArcLink communication between

the wire drive and control box of boom
systems

3. Multiple feeders are connected to the

power source.

1. A dual procedure gun is being used with

the dual procedure switch closed.

Possible Adjustments

1. Verify the user interface DIP is in the cor-

rect position.

1. Check that the electrode slides easily

through the gun and cable.

2. Remove tight bends from the gun and

cable.

3. Check that the spindle brake is not too

tight.

4. Verify a high quality electrode is being

used.

5. Wait for the error to reset and the motor

to cool (approximately 1 minute).

1. Check that motor can turn freely when

idle arm is open.

2. Verify that the gears are free of debris

and dirt.

1. Connect the work sense lead to the work

in a location free of dirt, rust and paint.

2. Turn ON the power source.
3. Reset the circuit breakers.

4. Tighten, repair or replace the control

cable.

1. Check cables for good connections.

2. Check cables for good connections.

3. Upgrade the software in the power

source.

1. Change the position of the dual proce-

dure switch.

ArcLink System Error Codes