OPERATION
POWER FEED 84, POWER FEED 84 DUAL
recoMMended processes and eQuipMenT
recoMMended processes
• GMAW, GMAW-Pulse, GMAW-STT
• FCAW
• SMAW
• GTAW
• CAG
process liMiTaTions
• Processes must be within the duty cycle and rating of the wire
feeder.
eQuipMenT liMiTaTions
• The Power Feed 84 does not operate with LincNet Power
Sources.
• The power source may require a software update.
• If the Power Feed 84 has contactors or a gouging kit installed, the
power source software may require updated.
• Does not include weld cables
• Operates on 40 VDC input
• The user interface may be located a maximum of 200 feet away
from the wire drive.
• Must use newer gun adapter kits. Not compatible with K1500-1,
K1500-2, K1500-3, K1500-4 K1500-5 and K489-7 gun adapter
kits.
• A remote control/foot amptrol and a push-pull gun may not be
connected to the Power Feed 84 single simultaneously.
• Power Feed 84 user interfaces are not compatible with Power
Feed 10M wire drives.
• Power Feed 84 wire drives are not compatible with Power Feed
10M user interfaces.
• The Power Feed 84 with contactors or gouging kit may not be
connected to a system with a robotic wire drive.
• With the Power Feed 84, only one USB port may present
anywhere in the system.
recoMMended poWer sources
Power Wave 355M
Power Wave 455M
Power Wave 455M/STT
Power Wave 655R
Power Wave S350
Power Wave S500
Power Wave S700
Power Wave R350
Power Wave R500
Power Wave i400