B-35

OPERATION

POWER FEED 84, POWER FEED 84 DUAL

Parameter

Name and Description

P.504

Mode Select Panel Lock

Selects between several Mode Select Panel lockout preferences. When a Mode
SelectPanelselectionislockedandanattemptismadetochangethatparameter,
amessagewillbedisplayedonthelowerdisplayindicatingtheparameterislocked.
•AllMSPOptionsUnlocked=AlladjustableparametersontheModeSelectPanel

areunlocked.

•All MSP Options Locked = All knobs and buttons on the Mode Select Panel are

locked.

•Start&EndOptionsLocked=TheStartandEndparametersontheModeSelect

Panelarelocked,allothersareunlocked.

•WeldModeOptionLocked=TheweldmodecannotbechangedfromtheMode

SelectPanel,allothersModeSelectPanelsettingsareunlocked.

•Wave Control Options Locked = The Wave Control parameters on the Mode

SelectPanelarelocked,allothersareunlocked.

•Start,End,WaveOptionsLocked=TheStart,EndandWaveControlparameters

ontheModeSelectPanelarelocked,allothersareunlocked.

•Start,End,ModeOptionsLocked=TheStart,EndandWeldModeSelectpara-

metersontheModeSelectPanelarelocked,allothersareunlocked.

ThisparametercanonlybeaccessedusingPowerWaveManagersoftware.

P.505

Setup Menu Lock

Determinesifthesetupparameterscanbemodifiedbytheoperatorwithout
enteringapasscode.

•No=The operator can change any set menu parameter without first

enteringthepasscodeevenifthepasscodeisnon-zero(default).

•Yes=Theoperatormustenterthepasscode(ifthepasscodeisnon-zero)

inordertochangeanysetupmenuparameters.

ThisparametercanonlybeaccessedusingPowerWaveManager.

P.506

Set User Interface Passcode

Preventsunauthorizedchangestotheequipment.Thedefaultpasscodeis
zero which allows full access. A nonzero passcode will prevent unautho-
rized: changes to memory limits, saving to memory (if P.502 = Yes),
changestosetupparameters(ifP.505=Yes).

If someone repeatedly enters an invalid passcode 5 times in a row, the
passcodewillbeautomaticallysetto9999,whichisaninvalidcodeandthe
interface can no longer be unlocked. PWManager is required to reset the
passcodeorunlockthemachine.

This parameter can only be accessed using Power Wave Manager soft-
ware.

USER DEFINED PARAMETERS

Range

AllMSPOptions

Unlocked

AllMSPOptions

Locked

Start&End

OptionsLocked

WeldModeOption

Locked

WaveControl

OptionsLocked

Start,EndWave

OptionsLocked

Start,End,Mode

OptionsLocked