beautypg.com

Saving a trace capture – Teledyne LeCroy SierraNet M408 User Manual Ver.1.40 User Manual

Page 66

background image

Teledyne LeCroy

Trigger and Filter Settings in Easy Mode

64

 

 

SierraNet M408 User Manual

Capture different patterns pre‐ and post‐trigger (see 

“Patterns and Data Capture 

Setup” on page 67

).

Exclude parameters from capture (see 

“Patterns and Data Capture Setup” on 

page 67

).

Trigger on a pattern or sequence of patterns (see 

“Trigger Setup” on page 137

).

Configure trace capture memory 

Select file to save trace capture in memory 

Saving a Trace Capture

You can save a Trace Capture for review at a later time using the Save As dialog. 

Figure 2.35: Save As Dialog

You can limit the range of the saved file. You can save:

All Packets

A range between selected cursors

A range between selected level of decoding. The levels allowed are dependent 
on the traffic in the trace. A trace with only Switch traffic might have the follow‐
ing levels available: ELS Cmd, Frame, GS Cmd, Sequence and SW Cmd, whereas a 
read‐write trace might have Frame, SCSI Cmd and Sequence available. 

Only Save Displayed Events: Click the checkbox to save only the Filtered in data in the 
trace.