5 available resources – Teledyne LeCroy SierraNet M408 User Manual Ver.1.40 User Manual
Page 213
SierraNet M408 Protocol Analyzer User Manual
211
InFusion Scenarios
LeCroy Corporation
4.5.5
Available Resources
You can specify Events, Combined Events and Actions and additional Events. The
application automatically checks for the maximum number of terms (Events/Actions).
When you exceed the limit, an error is flagged, prompting you to jump to the place that
caused the error.
The list of available resources for Ethernet is given below:
Symbol Detector(each has its own Embedded counter) X 4
Auto‐Neg Detector X 4
Counter X 12
Frame Detector X 8
Timer X 8
Frame Jammer X 8
Symbol Substitute X 16
Aut‐Neg Jammer X 4
Capture DWORD slot X 8
Insert/Save frame slot (up to 16K bytes) X 7
Insert BYTEs/Symbols inside frame (up to 128 bytes) X 8
Global Action Register X 8
State per sequencer X 256
Action Register per state X 8
Usage of Action Register:
Each Counter in Global Rules = 1
Each Counter in State = 1
Each Timer in Global Rules = 2
Each Timer in State = 3
Other Actions = 1
The list of available resources for Fibre Channel is given below:
Symbol Detector (each has its own Embedded counter) X 4
Ordered‐set Detector (each has its own Embedded counter) X 8
Pattern (32bit) Detector (each has its own Embedded counter) X 12
Training Sequence Detector X 4
Counter X 12
Frame Detector X 8
Timer X 8
Frame Jammer X 8
Symbol Substitute X 4
Pattern/Orderded‐set Substitute X 12 (shared with Pattern detectors)
Training Sequence Jammer X 4
Capture DWORD slot X 8
Insert frame slot (up to 4K bytes) X 1
Insert DWORD inside frame (up to 64 bytes) X 8
Global Action Register X 8
State per sequencer X 256
Action Register per state X 8