In the
FC 16G PE Detection Tab y
ou can select which Protocol Errors the analyzer will show
and which will be ignored. Select one or more protocol errors or select the Check All box
to select all. Enter the Number of Segments in the field.
Figure 2.27: FC 16G PE Detection Tab - Recording Settings Dialog
2.5.5
Trigger/Filter Settings Pane
Use the Trigger/Filter Settings pane to select Snapshot or Event Trigger mode and choose
the Trigger Filter settings. The default mode is Snapshot. See
You can configure the following settings from this dialog:
Select New from the dropdown menu to create new trigger filter settings. The
Trigger Filter Settings dialog displays a name adding a new sequential Trigger Fil‐
ter Setting. You can change the default name by typing a new name.
Select Manage from the dropdown menu to manage the trigger filter settings
(Choosing the Event Trigger option enables Trigger Position to set it manually.
You can set the trigger position in the captured buffer as a percentage of the
segment size. Trigger point of 0% means the trigger point will be on the first