6. Repeat steps 4 and 5 approximately three times, until the card is free from the 

retaining screws and you can remove the card from the system.

1.4.2

Cascading with CATC SYNC Expansion

You can use cascading of analyzer units for higher port count, by connecting the units 
through the optional CATC SYNC Expansion Card on the analyzer back.

Connecting Two

SierraNet M408

Analyzers via the CATC Sync Expansion Card (ACC-EXP-

002-X)

Multiple SierraNet M408 Analyzers can be connected using their CATC Sync ports which 
require an optional expansion card (ACC‐EXP‐002‐X).

Note:

Refer to relevant protocol analyzer user manual for instructions on how to install the expansion 

card.

To do so perform the following steps:

1. Make sure to stop any recordings in progress.

Note:

You may plug/unplug the sync cable while the analyzer unit is powered on.

2. Connect the female end of the sync cable to the SYNC OUT port of one SierraNet 

M408.