Caution – IAI America RCM-GW-CC User Manual
Page 9
![background image](/manuals/350335/9/background.png)
5
Operation mode and primary functions
Positioning data designated
mode
Primary functions
Position data
limit designated
mode
Position No.
designated
mode
Normal
positioning
mode
Push
operation
mode
Simple direct
value/Position
No. designated
mode
Position data
designated operation
○
×
○
○
○
Speed, acceleration
and deceleration direct
designation
Ч
Ч
○
○
Ч
Push operation
Ч
○
Ч
○
○
Present position
reading
○
○
○
○
Position No. designated
operation
Ч
○
Ч
Ч
○
Completed position No.
reading
Ч
○
Ч
Ч
○
Connectable axis
number
14 14 7 3 16
Settable axis No. (*1)
0 - 13
0 - 13
0 - 6
0 - 2
0 - 15
Position data
designated maximum
value (*2)
327.67mm
Designated
to position
table
327.67mm 9999.99mm
Operable CC-Link
version
Ver. 1, Ver. 2
Ver. 2
CAUTION
*1 A range of effective axis No. which is set to axis connected by SIO communication. Values set
exceeding this range are ignored. This case does not generate an alarm.
*2 In the case of position data direct designated operation, maximum value of position data is limited by
limiting data length of input and output register.