beautypg.com

IAI America RCM-GW-CC User Manual

Page 57

background image

53

(1) Address

configuration

In this mode, input and output for gateway control signal consist of two words respectively, and control
signal for each axis consists of six words respectively for input register and three words respectively for
output register.
Further, axis No.0 uses bit register, and axis No.1 and 2 use word register.
Numeric values in the parentheses represent axis Nos.


PLC

output⇒Gateway unit⇒Each axis input

Each axis output⇒Gateway unit⇒PLC input

Output

register

bF

Higher byte

b8

b7

Lower byte

b0

Input

register

bF

Higher byte

b8

b7

Lower byte

b0

RY 0F – 00

Position data designation (0)

RX 0F – 00

Status signal (0)

RY 1F – 10

Current limit value

(0)

Position data

designation (0)

RX 1F – 10

Present position data (0)

RY 2F – 20

Speed designation (0)

RX 2F – 20

Cannot be used

Present position

data (0)

RY 3F – 30

Acceleration and

deceleration

designation (0)

Speed

designation (0)

RX 3F – 30

RY 4F – 40

Positioning width designation (0)

RX 4F – 40

RY 5F – 50

Control signal (0)

Positioning width

designation (0)

RX 5F – 50

RY 6F – 60

Cannot be used

RX 6F – 60

Cannot be used

RY 7F – 70

Prohibited from use because this is in
CC-Link system region

RX 7F – 70

Prohibited from use because this is in
CC-Link system region



Output (writing) Register=Word register

Input (writing) Register=Word register

RWw 0

Gateway control signal 0

RWr 0

Gateway status signal 0

RWw 1

Gateway control signal 1

RWr 1

Gateway status signal 1

RWw 2

Position data designation (1)

RWr 2

Status signal (1)

RWw 3

Current limit value

(1)

Position data

designation (1)

RWr 3

Present position data (1)

RWw 4

Speed designation (1)

RWr 4

Cannot be used

Present position

data (1)

RWw 5

Position data

designation (1)

Speed

designation (1)

RWr 5

Status signal (2)

RWw 6

Positioning width designation (1)

RWr 6

Present position data (2)

RWw 7

Control signal (1)

Positioning width

designation (1)

RWr 7

Cannot be used

Present position

data (2)

RWw 8

Position data designation (2)

RWr 8

RWw 9

Current limit value

(2)

Position data

designation (2)

RWr 9

RWw A

Speed designation (2)

RWr A

RWw B

Position data

designation (2)

Speed

designation (2)

RWr B

RWw C

Positioning width designation (2)

RWr C

RWw D

Control signal (2)

Positioning width

designation (2)

RWr D

RWw E

RWr E

RWw F

Cannot be used

RWr F

Cannot be used