beautypg.com

IAI America RCM-GW-CC User Manual

Page 65

background image

61

6.6.2 Assignment for each axis

Input and output signals for each axis position No. designated mode and those in simple direct value
mode are different from each other in size of region and its content. Further, in the position No.
designated mode, meaning of each bit depends on the pattern set by gateway control signal PPS.

(1) Control signal and status signal of position No. designated axis

Pattern 0
(Standard)

Pattern 1
(Teach)

Pattern 2
(Positioning 256
points)

Pattern 3
(Positioning 512
points)

Pattern 4
(Air cylinder)

PLC

output R

W

w

PLC

input R

W

r


Pattern 0


Pattern 1


Pattern 2


Pattern 3


Pattern 4

Control signal

Command position No.

Control signal

Command position No.

Control signal

Command position No.

Control signal

Command position No.

Control signal

Start position No.

Status signal

Completed position No.

Status signal

Completed position No.

Status signal

Completed position No.

Completed position No.

Status signal

Completed position No.

Status signal