6. Address configuration of gateway


As described in 1.4 Features of gateway unit, actuators can be roughly operated by five modes.
Address configuration as a slave depends on each mode.

6.1 Gateway control signal

This is a signal to control the gateway, and consists of respective two words of word register for input and
output.
It is recommended to use data of this word register on the bit register by performing transmission processing.
ON/OFF control for communication of SIO link, and monitoring of communication status of SIO link and status
of gateway can be performed.

PLC output


1 word = 16 bits

Gateway

control

signal 0

Gateway

control

signal 1

PLC input

1 word = 16 bits

(RY00)

(RY10)

(RX00)

(RX10)

Gateway

status

signal 0

Gateway

status

signal 1