In this mode, the input and output signal for gateway control signals consist of two words respectively,
and control signals for each axis consist of one byte respectively for input and output bit register and one
byte respectively in input and output word register.
Numeric values in the parentheses represent axis Nos.


PLC

output⇒Gateway unit⇒Each axis input

Each axis output⇒Gateway unit⇒PLC input

Output

register

bF

Higher byte

b8

b7

Lower byte

b0

Input

register

bF

Higher byte

b8

b7

Lower byte

b0

RY 0F – 00 Control signal (1)

Control signal (0)

RX 0F – 00

Status signal (1)

Status signal (0)

RY 1F – 10 Control signal (3)

Control signal (2)

RX 1F – 10

Status signal (3)

Status signal (2)

RY 2F – 20 Control signal (5)

Control signal (4)

RX 2F – 20

Status signal (5)

Status signal (4)

RY 3F – 30 Control signal (7)

Control signal (6)

RX 3F – 30

Status signal (7)

Status signal (6)

RY 4F – 40 Control signal (9)

Control signal (8)

RX 4F – 40

Status signal (9)

Status signal (8)

RY 5F – 50 Control signal (11) Control signal (10)

RX 5F – 50

Status signal (11)

Status signal (10)

RY 6F – 60 Control signal (13) Control signal (12)

RX 6F – 60

Status signal (13)

Status signal (12)

RY 7F – 70 Prohibited to use because this is in

CC-Link system region

RX 7F – 70

Prohibited to use because this is in
CC-Link system region



Output (writing) Register=Word register

Input (writing) Register=Word register

RWw 0

Gateway control signal 0

RWr 0

Gateway status signal 0

RWw 1

Gateway control signal 1

RWr 1

Gateway status signal 1

RWw 2

Command

position No. (1)

Command

position No. (0)

RWr 2

Completion No. +

zone signal (1)

Completion No. +

zone signal (0)

RWw 3

Command

position No. (3)

Command

position No. (2)

RWr 3

Completion No. +

zone signal (3)

Completion No. +

zone signal (2)

RWw 4

Command

position No. (5)

Command

position No. (4)

RWr 4

Completion No. +

zone signal (5)

Completion No. +

zone signal (4)

RWw 5

Command

position No. (7)

Command

position No. (6)

RWr 5

Completion No. +

zone signal (7)

Completion No. +

zone signal (6)

RWw 6

Command

position No. (9)

Command

position No. (8)

RWr 6

Completion No. +

zone signal (9)

Completion No. +

zone signal (8)

RWw 7

Command

position No. (11)

Command

position No. (10)

RWr 7

Completion No. +

zone signal (11)

Completion No. +

zone signal (10)

RWw 8

Command

position No. (13)

Command

position No. (12)

RWr 8

Completion No. +

zone signal (13)

Completion No. +

zone signal (12)

RWw 9

RWr 9

RWw A

RWr A

RWw B

RWr B

RWw C

RWr C

RWw D

RWr D

RWw E

RWr E

RWw F

Cannot be used

RWr F

Cannot be used