(2) Assignment for every axis

Control signal and status signal are set by ON/OFF signal in bit units, and acceleration and deceleration
are set by binary data of one byte (8 bits). Further, speed, position data designation and present position
data can be handled in binary data of one word (16 bits), and the PLC can handle numeric values of
–32,768 to +32,767.
Set the acceleration and deceleration and speed in a range of specification of the actuator, and set
position data in a range of soft stroke.




1 word = 16 bits

PLC output

PLC input

1 word = 16 bits

Speed

Acceleration and deceleration speed

Control signal

1 word = 16 bits

Cannot be used

Command position No.

Unit: Acceleration and deceleration = 0.01G Speed = 1/100mm/sec Position data = 1/100mm

Position data designation Integer with sign

Present position Integer with sign

(Sign)