37

Signal type

Bit

Signal

name

Contents

15 RUN

Gateway unit now normally
operating output

This is turned ON while
gateway unit is normally
operating. This is synchronized
with light up of the LED (RUN)
on the front of the unit.

14 G.ER

Gateway unit error detection output

This is turned ON when major
fault stop status is detected.
This is synchronized with light
up of the LED (G.ER) on the
front of the unit.

13 T.ER

SIO link communication error
detection output

This is turned ON when
communication error of the SIO
link is detected. This is
synchronized with light up of the
LED (T.ER) on the front of the
unit.

12 TPC

Port switch ON output

This outputs status of the port
switch on the front of the unit.
This is turned ON when the port
switch is ON.

11

MOD4

Mode setting switch 4 ON output

10

MOD3

Mode setting switch 3 ON output

9

MOD2

Mode setting switch 2 ON output

8

MOD1

Mode setting switch 1 ON output

This outputs setting status of
the mode setting switch.

7 Major

V.4

6 Major

V.2

5 Major

V.1

Outputs Major Version No. by 3 bit
binary.

4 Minor

V.16

3 Minor

V.8

2 Minor

V.4

1 Minor

V.2

Control

signal 0

0 Minor

V.1

Outputs Minor Version No. by 5 bit
binary.

This outputs version information
of gateway unit. This may be
checked when any fault occurs.
Keep this in a status that this is
read by the PLC.
Example) In the case of Ver.
1.03
Major Version No.=1
(Data is 001)
Minor Version No.=3
(Data is 0011)

15

LINK15

Link is being connected. Axis No.15

14 LINK14

14

13 LINK13

13

12 LINK12

12

11 LINK11

11

10 LINK10

10

9 LINK9

9

8 LINK8

8

7 LINK7

7

6 LINK6

6

5 LINK5

5

4 LINK4

4

3 LINK3

3

2 LINK2

2

1 LINK1

1

PLC input

Control

signal 1

0 LINK0

0

For axis for which link
connection is selected by
CFG15-0, link connection
becomes effective when MON
signal is ON.
Signal for link connection
effective axis is turned ON.