Section 7: Fieldbus Interface
05/11 89
51209 Revision 2
7.3.6
Register 5: Device Type and Software Release
Only reading is permitted.
Bit 7
Bit 6
Bit 5
Bit 4
Bit 3
Bit 2
Bit 1
Bit 0
Byte 0
TYPE MSB
Byte 1
TYPE LSB
Byte 2
MAINVERSION
Byte 3
SUBVERSION
E.g. 5220 Rel 1.23 = 52200123
hex
7.3.7
Register 6: Board Number
Only reading is permitted.
Bit 7
Bit 6
Bit 5
Bit 4
Bit 3
Bit 2
Bit 1
Bit 0
Byte 0
Board number MSB
Byte 1
""
Byte 2
""
Byte 3
Board number LSB
E.g. 148388723 = 08D83B73
hex
7.3.8
Register 7: (Reserved)
7.3.9
Register 8 ...15: Weight Data
Only reading is permitted.
The gross, net and tare weight are stored as DINT fixpoint.
The real data value is derived from DINT and EXPO as follows :
Value
Real
=reading
DINT
*10
(-EXPO
Register 8
Current gross value
Register 9
Current net value, if tared; otherwise gross
Register10 Current tare value, if tared, otherwise 0
Register11 Value on the front-panel display
Register12 Reserved
Register13 Reserved
Register14 Max (FSD)
Register15 Reserved (free)
7.3.10 Register 22 ... 27: Limit Values (Read/Write)
Register 22
Limit 1 on
Register 23
Limit 1 off
Register 24
Limit 2 on
Register 25
Limit 2 off
Register 26
Limit 3 on
Register 27
Limit 3 off