Fairbanks X SERIES PR 5220 ETHERNET TRANSMITTER User Manual
Page 21
Section 3: Installing the Instrument
05/11 22
51209 Revision 2
3.2.8
Analog Output
Connection method:
4-pin plug-in terminal block
Number of outputs:
1 current output, output
voltage via external resistor
Output:
Gross, net weight or via
Profibus
Range:
0/4 ... 20mA, configurable
Resolution:
E.g. 0 - 20 mA in max.
40,000 counts
Linearity error:
@ 0 - 20mA: <0,05 %
@ 4 - 20 mA: <0,025 %
Temperature effect:
< 100 ppm/K
Load:
0 ... max. 500 ohms
Protected against short
circuit:
Yes
Electrical isolation:
Yes
Cable length (shielded):
150 m (current output)
0/4 ... 20mA
Analog signal,
current output.
The current is supplied
directly via the terminals.
0 ... 10V
Analog signal,
voltage output
The voltage level
corresponds to the voltage
drop across the 500-ohm-
(10 ppm/K) resistor.