beautypg.com

Fairbanks X SERIES PR 5220 ETHERNET TRANSMITTER User Manual

Page 21

background image

Section 3: Installing the Instrument

05/11 22

51209 Revision 2

3.2.8

Analog Output

Connection method:

4-pin plug-in terminal block

Number of outputs:

1 current output, output
voltage via external resistor

Output:

Gross, net weight or via
Profibus

Range:

0/4 ... 20mA, configurable

Resolution:

E.g. 0 - 20 mA in max.
40,000 counts

Linearity error:

@ 0 - 20mA: <0,05 %
@ 4 - 20 mA: <0,025 %

Temperature effect:

< 100 ppm/K

Load:

0 ... max. 500 ohms

Protected against short
circuit:

Yes

Electrical isolation:

Yes

Cable length (shielded):

150 m (current output)

0/4 ... 20mA

Analog signal,
current output.

The current is supplied
directly via the terminals.

0 ... 10V

Analog signal,
voltage output

The voltage level
corresponds to the voltage
drop across the 500-ohm-
(10 ppm/K) resistor.