Section 5: Commissioning

05/11 52

51209 Revision 2

5.6.4

Fieldbus Parameters

Setup

Serial ports parameter

Operating parameter

Fieldbus parameter

Press

and

to select [Fieldbus parameter]


This menu item can only be selected if the instrument is a PR5220/01 or a PR5220/04 version.
The instrument version automatically determines the corresponding protocol:
[Profibus-DP] for PR5220/01 and [DeviceNet] for PRPR5220/04.
Dependent on the interface type, additional parameters are required:

[Profibus-DP]

Setup/Fieldbusparameter

Protocol

Profibus-DP

Profibus-DP Address

1


[DeviceNet]

Setup/Fieldbus

Protocol

DeviceNet

DeviceNet baudrate

500k Press

to select 500, 250 or 125 k.

DeviceNet MAC-ID

1 Select address 1 ... 62


Closing the menu

Save changes ?

To close the menu, press

. Reply [Yes] to save the data,