Section 5: Commissioning
05/11 52
51209 Revision 2
5.6.4
Fieldbus Parameters
Setup
Serial ports parameter
Operating parameter
Fieldbus parameter
Press
and
to select [Fieldbus parameter]
This menu item can only be selected if the instrument is a PR5220/01 or a PR5220/04 version.
The instrument version automatically determines the corresponding protocol:
[Profibus-DP] for PR5220/01 and [DeviceNet] for PRPR5220/04.
Dependent on the interface type, additional parameters are required:
[Profibus-DP]
Setup/Fieldbusparameter
Protocol
Profibus-DP
Profibus-DP Address
1
[DeviceNet]
Setup/Fieldbus
Protocol
DeviceNet
DeviceNet baudrate
500k Press
to select 500, 250 or 125 k.
DeviceNet MAC-ID
1 Select address 1 ... 62
Closing the menu
Save changes ?
To close the menu, press
. Reply [Yes] to save the data,
or [No] to close the menu without changing data.