Section 5: Commissioning

05/11 51

51209 Revision 2

5.6.3

Operating Parameters


Define the basic operating parameters under

-[

Operating parameter

].

Setup/Operating parameter

AccessCode

0

SetTareKey

tare & reset tare

SetZeroKey

only when not tared

[AccessCode]
The access code can be used to protect the [Setup] from unauthorized operation. Enter a number
with up to 6 digits. As long as you are in this menu, the value can be overwritten as required. When
[AccessCode] is set to 0, no access code ist prompted.

[SetTareKey]
The SetTare function can be configured (VNC operation / Internet browser).
[tare & reset tare]: the scale is tared if it was not tared previously; otherwise, tare is reset.
[tare & tare again]: when you press the [Tare] key, the current value is stored in the tare memory
and a net weight of 0 is displayed.
[disabled]: The tare key has no function.

[SetZeroKey]
The SetZero function (VNC operation / Internet browser) can be limited to gross mode with [only
when not tared] or switch the scale to gross mode automatically with [reset tare on zeroset]. If the
zero-setting key with these settings has no effect, the configured zero-setting range (around the
zero-point set with the dead load) is already utilized due to a previous zero-setting operation and/or
automatic zero setting.
[disabled]: The key has no function.

Save changes ?

To close the menu, press

. Press [Yes] to save the data,

or [No] to close the menu without changing data.