Section 5: Commissioning

05/11 59

51209 Revision 2

If the limits (Limit 1 and Limit
2) for 'On' and 'Off' are equal
(on = off), output 1 (Limit 1
out) switches ON, when the
weight (Wgt) exceeds the
value and output 2 (Limit 2
out) switches OFF, when the
weight drops below the value.

Setup/Limit parameter

Limit 1 on

900 kg

Action

set marker 1

X64=1

Condition

no condition

-----

1. Determining an action
Determine the action for the rising edge of the reference signal under [Limit 1 on] from the following
list (here: Marker 1 is set when 900 kg are exceeded).
Accordingly, an action for [Limit 1 off] can be determined.

Function

SPM bit

-no action-

-----

No function

set marker 1

X64=1

Set marker 1

set marker 2

X65=1

Set marker 2

set marker 3

X66=1

Set marker 3

select net

X72=1

Select net

set zero

X112=1

Set zero

set tare

X113=1

Set tare

reset tare

X114=1

Reset tare

set test

X115=1

Activate the analog test

reset test

X116=1

Finish the analog test

reset PWF

X117=1

Reset power fail

set fixtare

X118=1

Set fixtare (use the value in address D31 as a tare value)

get fixtare

X119=1

Save gross value as fixtare in address D31

set print

X120=1

Activate a print order ?

clr marker 1

X64=0

Clear marker 1

clr marker 2

X65=0

Clear marker 2

clr marker 3

X66=0

Clear marker 3

select gross

X72=0

Save the gross weight in address D11


2. Determining a condition
Additionally, a condition [Condition] can be assigned to the signal; see Chapter 5.7.4.