Section 3: Installing the Instrument

05/11 24

51209 Revision 2

3.2.10 3 Optocoupler Outputs


The optocoupler outputs have one common potential (GND) for the output group that is separated
from the common potential of the input group.

Connection method:

4-pin plug-in terminal block

Cable:

Shielded, max. 50 m

Number of outputs:

3

Output signal:

External supply required

Output current:

Max. 30 mA

Output voltage:

Max. switching voltage: 28 VDC

Electrical isolation:

Yes; a common minus potential for the
group of 3 outputs



Example: relay control connection

When output 1 is active (true), the relay switches.
For protection of the output circuit, relays with free-
wheel diode must be provided.



Example: voltage output connection

When output 1 is active (true), the output voltage
changes from 24 /12 VDC into < 3 VDC. A load
resistance of 2.2 /1 kohms must be provided.