Section 5: Commissioning

05/11 46

51209 Revision 2

WP A/Calibration

Tare timeout

2.5 s

Zeroset range

50.00 d

Zerotrack range

0.25 d

Zerotrack step

0.25 d

Zerotrack time

0.0 s

Overload

9 d


[Tare timeout]
Enter a timeout value between 0.1 and 25 s for a taring/zero set command that cannot be executed
(e.g., if scale mechanically unstable, filter settings faulty, resolution too high, stability condition too
narrow).

[Zeroset range]
Determine a +/- range around the zero point determined by the dead load during calibration; within
this range:
- the displayed gross weight can be set to zero by pressing the zero-setting key (or by a

corresponding external command), and

- automatic zero tracking is active

Available range: 0.00 d to 10000.00d

In 'legal-for-trade' mode a value <= 2 % of Max. must be entered. Example: 60 d for 3000e,
class III.

[Zerotrack range]
Range within which automatic zero tracking compensates deviations; 0.25 to 10000.00d. In 'legal-
for-trade' mode a value of 0.25 d has to be entered.

[Zerotrack step]
Step for automatic tracking; 0.25 to 10d. In 'legal-for-trade' mode a value of 0.25 d has to be
entered.

[Zerotrack time]
Enter a time interval for automatic zero tracking within 0.0 (tracking switched off) and 25 s. In 'legal-
for-trade' mode a value of 0.25 d has to be entered.

[Overload]
Weighing range above the maximum capacity (Max), without error message. Available range: 0 to
9999900 d. In 'legal-for-trade' mode max. 9 d=e has to be entered.

WP A/Calibration

Min

50 d

Range mode

Single range


[Min]
Minimum weight at which a print command can still be executed. Range is 0 to 9999900 d.
In 'legal-for-trade' mode min. 20 d has to be entered.