Fairbanks X SERIES PR 5220 ETHERNET TRANSMITTER User Manual
Page 77
Section 6: SMA Protocol
05/11 78
51209 Revision 2
6.6.5
Reply with ‘A’ and ‘B’ Command
Reply format with ‘A' and 'B' commands (variable length):
The reply format and meaning are:
Start of reply from 'A'/'B' command
The field name is three characters long, left-adjusted and filled up with spaces on
the right, if necessary.
The following fields are sent:
“SMA” level/revision
(reply from ‘A’ command)
“MFG” manufacturer marking
(reply from the 1st ‘B’ command)
“MOD” product / model identification
(reply from the 2nd ‘B’ command)
“REV” software version
(reply from the 3rd ‘B’ command)
“SN_“ serial number
(reply from the 4th ‘B’ command)
“END”: This is always the last inscription field
(reply from the last ‘B’ command)
‘:’
Separator between field name and field content.
The data field has up to 25 characters.
The SMA field contains
with the following meaning: level= (1, 2, etc.); revision= (1.0, 1.1, etc.)
End of reply from 'A'/'B' command
Example:
Command
Reply
Note: If the controlling computer sends another 'B' command: