Page 12: General technical data

12
TechnicalData
6.
Technical daTa
6.1.
Operating conditions
Permitted ambient temperature:
(operation and storage)
0 ... +70 °C
Max. permitted humidity:
≤ 80 %, non condensing
Protection class:
IP65 to EN 60529
6.2.
conformity with the following standards
CE mark conforms to
EMC Directive:
EN61326
6.3.
general Technical data
Materials
Housing, cover:
PC, + 20 % glass fiber
Front plate foil:
Polyester
Screws:
Stainless steel
Multipin:
CuZn, nickel-plated
Wall assembly bracket:
PVC
assembly
Installation position:
Any position
Assembly models:
Attachment to a pipeline with Bürkert flow-rate fitting Type S030
wall assembly, rail assembly, valve assembly, control cabinet assembly
Display:
2-line, (see “Figure 10: Display elements”)
Operating voltage:
Multipin: 3-pin or / and 4-pin M8, 8-pin M12
Power cable:
0.5 mm
2
max. cross section,
max. 100 m long, screened
english