XDCR MNT -- Transducer Mounting Method (Choice)

1. V
2. W
3. Z


Selects the mounting orientation for the transducers. The selection
of an appropriate mounting orientation is based on pipe and liquid
characteristics. See Part 2 – Transducer & RTD Installation in this
manual.

PIPE OD -- Pipe Outside Diameter Entry (Value)

1. ENGLSH

(Inches)

2. METRIC

(Millimeters)


Enter the pipe outside diameter in inches if Englsh was selected as
Units; in millimeters if Metric was selected.

PIPE WT -- Pipe Wall Thickness Entry (Value)

1. ENGLSH

(Inches)

2. METRIC

(Millimeters)


Enter the pipe wall thickness in inches if Englsh was selected as
Units; in millimeters if Metric was selected.

PIPE MAT -- Pipe Material Selection (Choice)

1. Acrylic

(ACRYLIC)

2. Aluminum

(ALUMINUM)

3. Brass [Naval]

(BRASS)

4. Carbon Steel

(CARB

ST)

5. Cast Iron

(CAST

IRN)

6. Copper (COPPER)
7.
Ductile Iron

(DCTL

IRN)

8. Fiberglass-Epoxy (FBRGLASS)
9.
Glass Pyrex

(PYREX)

10. Nylon

(NYLON)

11. HD Polyethylene (HDPE)
12.
LD Polyethylene (LDPE)
13. Polypropylene

(POLYPRO)

14. PVC CPVC

(PVC/CPVC)

15. PVDF (PVDF)

Pipe
Diameter

Pipe
Material

Pipe Wall
Thickness

PART 3 - KEYPAD CONFIGURATION