beautypg.com

Datamax-O'Neil A-Class Mark II Operator’s Manual User Manual

Page 92

background image

82

A-Class Mark II

Step

Action

Displayed Message

Comment

O

Using the DOWN Key set

the ‘Paper’ level to the
value determined in the

previous step and press
the ENTER Key.

Repeat this step for the
‘Gap’ (or ‘Mark’) and the

‘Empty’ value.

PAPER SENSOR LEVEL

P* 198 G*000 E*000

GAP SENSOR LEVEL

P* 198 G*084 E*000

EMPTY SENSOR LEVEL

P* 198 G*084 E*014

-Or, for reflective media:

PAPER SENSOR LEVEL

P* 015 G*000 E*000

GAP SENSOR LEVEL

P* 015 G*181 E*000

EMPTY SENSOR LEVEL

P* 015 G*181 E*213

The selection will change to

indicate the item for entry.

P

Press the ESC Key

repeatedly to exit the
menu and, when

prompted, save the
changes.

SAVE CHANGES?

NO YES

Selecting YES saves the settings,

while NO discards them.

(Continued)