A-Class Mark II

Media Settings (continued)

Menu Item

Details

RIBBON LOW OPTIONS

Defines the response when THERMAL TRANSFER is
selected and the ribbon supply diminishes, where:

RIBBON LOW DIAMETER

Sets the threshold that will trigger a Low Ribbon

Warning prompt, where:

(1.0

0 – 2.00 in.)

1.38

Is the outer diameter size of the roll.

PAUSE ON RIBBON LOW

Sets the printer to pause when the Ribbon Low

Diameter setting is met, where:

ENABLED

Forces you to press the PAUSE Key to proceed with the
print job.

DISABLED

Allows printing to continue until ribbon empty is

declared.

SENSOR CALIBRATION

Selects the method that is used to calibrate the media

sensor (see Section 5.2), where:

PERFORM CALIBRATION

Allows automatic calibration, where:

YES

Establishes the best values based on sampled
readings.

NO

Exits the menu item without changing the current

settings.

ADVANCED ENTRY

Sets the values via manual entry process, where:

PAPER SENSOR LEVEL
170 (0 – 255)

Establishes the threshold value for standard paper.

REFL PAPER LEVEL
020 (0 – 255)

Establishes the threshold value for reflective paper.

GAP SENSOR LEVEL
016 (0 – 255)

Establishes the threshold value for the gap/notch.

MARK SENSOR LEVEL
230 (0 – 255)

Establishes the threshold value for the reflective mark.

EMPTY SENSOR LEVEL
009 (0 – 255)

Establishes the threshold value for the empty

condition.

TRAN SENSOR GAIN
31 (0 – 31)

Establishes the sensitivity of the gap/notch sensor.

REFL SENSOR GAIN
13 (0 – 31)

Establishes the sensitivity of the reflective sensor.