background image

42

A-Class Mark II

Printer Options (continued)

Menu Item

Details

TAG DATA SIZE

Sets the tag data size, where:

96-BIT

Selects 96 bits (24 hexadecimal characters or 12

ACSII characters).

64-BIT

Selects 64 bits (16 hexadecimal characters or 8 ACSII

characters).

POWER ADJUST

Adjusts the applied power, where:

(-04  04)
000

Is the power level, in 1.0 dBm increments.

KILL CODE

Sets the code to permanently deactivate the tag,
where:

00 00 00 00

Is the code, in the form B3, B2, B1, B0.

ACCESS CODE

Sets the code to protect tag memory contents, where:

00 00 00 00

Is the code, in the form B3, B2, B1, B0.

GEN 2 LOCK ACTION

Sets the lock for Gen 2 tags, where:

NONE

Does not lock the tag.

PERMALOCK

Locks data permanently.

PWD-READ/WRITE

Locks data with password-protection for writing data.

BOTH

Allows both Permalock and PWD-Lock to be used.

PAD/TRUNC. EPC DATA

Allows padding or truncating of data with nulls
(represented as “00”) in order to fit the selected EPC

Tag Data Size, where:

DISABLED

Does not pad or truncate data.

LEADING

Adds nulls to the front (left) of the data if less than the

size, or cuts the data if greater.

TRAILING

Adds nulls to the end (right) of the data if less than

the size, or cuts the data if greater.