42
A-Class Mark II
Printer Options (continued)
Menu Item
Details
TAG DATA SIZE
Sets the tag data size, where:
96-BIT
Selects 96 bits (24 hexadecimal characters or 12
ACSII characters).
64-BIT
Selects 64 bits (16 hexadecimal characters or 8 ACSII
characters).
POWER ADJUST
Adjusts the applied power, where:
(-04 04)
000
Is the power level, in 1.0 dBm increments.
KILL CODE
Sets the code to permanently deactivate the tag,
where:
00 00 00 00
Is the code, in the form B3, B2, B1, B0.
ACCESS CODE
Sets the code to protect tag memory contents, where:
00 00 00 00
Is the code, in the form B3, B2, B1, B0.
GEN 2 LOCK ACTION
Sets the lock for Gen 2 tags, where:
NONE
Does not lock the tag.
PERMALOCK
Locks data permanently.
PWD-READ/WRITE
Locks data with password-protection for writing data.
BOTH
Allows both Permalock and PWD-Lock to be used.
PAD/TRUNC. EPC DATA
Allows padding or truncating of data with nulls
(represented as “00”) in order to fit the selected EPC
Tag Data Size, where:
DISABLED
Does not pad or truncate data.
LEADING
Adds nulls to the front (left) of the data if less than the
size, or cuts the data if greater.
TRAILING
Adds nulls to the end (right) of the data if less than
the size, or cuts the data if greater.