beautypg.com

Datamax-O'Neil A-Class Mark II Operator’s Manual User Manual

Page 66

background image

56

A-Class Mark II

4.2.5 Communications


The Communications menu contains interface port and host control functions:

Menu Item

Details

SERIAL PORT A

Controls the RS-232 communications settings for
Serial Port A, where:

BAUD RATE

Sets the serial communication rate, where:

1200 BPS
2400 BPS
4800 BPS
9600 BPS
19200 BPS
28800 BPS
38400 BPS
57600 BPS
115000 BPS

Is the serial speed in Bits Per Second.

PROTOCOL

Sets the data flow control method (handshaking),
where:

BOTH

Uses XON/XOFF and CTS/DTR.

SOFTWARE

Uses XON/XOFF.

HARDWARE

Uses CTS/DTR.

NONE

Disables flow control.

PARITY

Sets word parity, where:

NONE

Uses parity.

ODD

Uses Odd parity.

EVEN

Uses Even parity.

DATA BITS

Sets Word length, where:

(7 – 8)
8

Is the number of bits in the word.

STOP BITS

Sets the stop bit count, where:

(1 – 2)
1

Is number of stop bits.