beautypg.com

Datamax-O'Neil A-Class Mark II Operator’s Manual User Manual

Page 144

background image

134

A-Class Mark II

GPI/O B (J2)

Six unassigned inputs are designed to interface to open-collector outputs. These inputs
require no external pull-ups and blocking diodes allow the use of totem pole outputs from +4.5

to + 26 VDC. Optical isolators are available to provide isolation. Two print control interface
circuit examples are given below.



For direct inputs:


Use the printer’s +5VDC and Ground to supply
the devices interfacing to the GPI/O B inputs (as

shown, right).

GPI/O B - J2

8

3

12

7

Input 1

Ground

13

Input 2

Input 3

Input 4

6

Input 5

Input 6

2








For isolated inputs:


To provide galvanic isolation for the GPI/O B

inputs, remove jumper JMP 11 then supply an
external +5VDC source voltage to Pin 1, and

remove jumper JMP 10 then supply an external
Ground to Pin 6 (as shown, right).




1 Vcc

+5 VDC External Source

GPI/O B - J2

8

3

12

7

Input 1

13

Input 2

Input 3

Input 4

Input 5

Input 6

2

Ground

6



Six unassigned outputs are programmable and slew-limited. Optional 10K ohm pull-up
resistors, one for each of the output lines, can be used at either +5 or +24 VDC via jumpers

JMP 2 – 7.

If external pull-up resistors are employed (that is, when Jumpers JMP 2 - 7 are not

installed), to avoid damage ensure that external voltage does not exceed +30VDC.