81

Step

Action

Displayed Message

Comment

M

Complete a table (see

example below) using
three new measurements,

as follows:

(A) Raise the printhead

assembly. Place the
label (attached to

liner) in the Media
Sensor then lower and

latch the Head Lift
Lever. Record the

sensor reading as P.


(B) Raise the printhead

assembly. Place the
liner, notch, or mark

in the Media Sensor
then lower and latch

the Head Lift Lever.
Record the sensor

reading as G (or M).


(C) Raise the printhead

assembly. Remove all
media from the Media

Sensor then lower and
latch the Head Lift

Lever. Record the
sensor reading as E.

GAIN TRAN

*18 (0 – 31)

- or, for reflective media:

GAIN REFL

*18 (0 – 31)

Where ‘yyy’ represents the current

sensor reading.

The re-sampled values may
differ from those previously
noted. This is normal; do not
readjust the Media Sensor.

N

Press the ESC Key and

then the DOWN Key. Press
the ENTER Key.

SENSOR LEVELS

The sensor readings must now be

entered into the printer.


Selected Gain Table

Gain Number

P (Paper)

G (Gap) or M (Mark)

E (Empty)

18 173 42

9