A-Class Mark II

Electrical

Power Supply:

Auto-ranging switching type.

AC Input Voltage Range:

90 – 132 / 180 – 264 VAC @ 47 – 63 Hz, auto-ranging

Grounding:

Unit must be connected to a properly grounded circuit.


A-4xxx models: 200 watts, typical operating;

25 watts, standby

Power Consumption:

A-6xxx models: 220 watts, typical operating;

25 watts, standby

Printhead Protection:

Thermistor sensor shutdown with over-temperature occurrence,
and automatic printing resumption after cooling.


Environmental

Operating Temperature:

32 F – 100 F (0 C – 38 C)

Operating Humidity:

10% – 90% (non-condensing)

Storage Temperature:

-40 F – 150 F (-40 C – 60 C)

Storage Humidity:

5% – 95% (non-condensing)

Dust: Non-conducting,

non-corrosive

Electromagnetic Radiation:

Moderate RF fields can be tolerated.


Mechanical

Height: All

models:

11.81 inches (30.0 cm)

Width:

All models:

9.67 inches (24.6 cm)

A-4xxx models:

15.35 inches (39.0 cm)

Depth:

A-6xxx models:

17.35 inches (44.0 cm)

A-4xxx models:

34 pounds (15.3 kg)

Weight:

A-6xxx models:

37 pounds (16.7 kg)