Printer Options (continued)

Menu Item

Details

GPIO PORT

Controls the optional Applicator Interface Card’s GPIO
function, where:

GPIO DEVICE

Sets the option to work with a specific device type,

where:

DISABLED

Disables the option.

APPLICATOR

Enables parameters for related label applicator
functions:

Completion upon last SOP, de-asserts Data Ready

(DRDY);

FEED allowed at any time; and,

DRDY upon PAUSE.

APPLICATOR 2

Enables parameters for alternate label applicator
functions:

Completion upon 1 msec. overlap of Data Ready

(DRDY) and End of Print (EOP);

DRDY signal end inhibits FEED; and,

De-asserts DRDY upon PAUSE or FAULT.

BARCODE VERIFIER

Enables the parameters for bar code verifier functions.

START OF PRINT

Selects the type of input signal required to initiate

printing, where:

LOW PULSE

Triggers printing with a low pulse.

HIGH PULSE

Triggers printing with a high pulse.

ACTIVE LOW

Triggers printing with a low signal.

ACTIVE HIGH

Triggers printing with a high signal.

EDGE

Triggers printing with a signal edge transition.