beautypg.com

Datamax-O'Neil A-Class Mark II Operator’s Manual User Manual

Page 142

background image

132

A-Class Mark II

GPI/O A (J1)

Four dedicated inputs are available for control of printer functions. These inputs require no
external pull-ups, are designed to interface to open-collector outputs and accept totem pole

outputs from +4.5 to + 26 VDC. Optical isolators are available to provide isolation. Two print
control circuit examples are given below.

For direct inputs –

Use the printer’s +5VDC and Ground to supply the
devices interfacing to the GPI/O A inputs (as

shown, right).

GPI/O A - J1

3

4

5

6

1

Start of Print

Slew Label

Toggle/Pause

Reprint

Ground





For isolated inputs –

To provide galvanic isolation for the GPI/O A
inputs, remove jumper JMP 9 then supply an

external +5VDC source voltage to Pin 2, and
remove jumper JMP 8 then supply an external

Ground to Pin 1 (as shown, right).


3

4

5

6

2

Start of Print

Slew Label

Toggle/Pause

Reprint

Vcc

+5 VDC External Source

GPI/O A - J1

1

Ground


Seven dedicated outputs are available for control, warning, and error functions. These open-
collector outputs are slew-limited. Optional 10K ohm pull-up resistors, tied to a common point
for use at either +5 or +24 VDC, are available via jumper JMP 1.

If external pull-up resistors are used (that is, without jumper JMP1 installed), then to

avoid damage ensure that a common external voltage not exceed +30VDC is used.





The table below details the GPI/O A pin assignments, settings and functions.