66

A-Class Mark II

Diagnostics (continued)

Menu Item

Details

PRINT TEST RATE (min)

Allows a label-to-label delay when batch printing Test
Labels, where:

000 (0 – 120)

Is the selected interval, in minutes.

SENSOR READINGS

Displays various sensor values (0 – 255), where:

THR TRAN RIBM 24V

127 159 093 175

PS HD RANK

00 254 125

Are readings for the printhead thermistor sensor

(THR), media “gap” (TRAN) or “reflective” (REFL)

sensor, ribbon sensor (RIBM), 24VDC power supply
sensor (24V), present sensor (PS), printhead assembly

sensor (HD), and printhead ranking resistor (RANK).
(The values given here are examples only.)

RIBBON SENSOR LIMITS

Displays ribbon sensor values for thermal transfer

equipped printers, where:

RIBBON ADC LOW

039

RIBBON ADC HIGH

250

Are the sensor readings. (The values given here are
examples only.)

iPH REPORT

Displays the IntelliSEAQ™ data (including the

printhead serial number, and installation and
maintenance dates) where:

VIEW

Displays the data.

PRINT

Prints the data:

SAVE

Saves the data to an external storage device; see
Section 2.3.5.

FLASH MODULE REPORT

Displays the status and error history of the internal

memory modules.

VIEW

Displays the data.

PRINT

Prints the data.

iPH REPORT
TUE 12:44PM 23MAY2006
4212-HE25-060224-090
PRINTHEAD SERIAL #: 5x-00289
PRINTHEAD MODEL # 163
PRINTER SERIAL # 60430014
PRINTHEAD INCHES 1334900
INSTALLATION DATE - INITIAL 02/02/2006
INSTALLATION DATE - LAST 08/06/2006
PRINTHEAD CLEANING
CLEAN PROCEDURES: 5
CLEAN COUNTER RESET 5
NUMBER OF INCHES LAST- 0