A-Class Mark II

79

Step

Action

Displayed Message

Comment

I

Lower and latch the Head
Lift Lever.


Using the UP or the DOWN

Key, set the Gain Number
to 00 and then press
ENTER.


Record this reading as a

TOF Value for Gain
Number 00 in the table.

GAIN TRAN

*00 (0 - 31)


- Or, for reflective media:

GAIN REFL

*00 (0 – 31)

Where ‘yyy’ represents the
current sensor reading.


After ENTER is pressed, an

asterisk (*) appears to denote
selection.

Sample Calibration Table

Gain Number

Label Value

TOF Value

Difference Value

00 252 248
01 250

02 248

… …

31 09


Step

Action

Displayed Message

Comment

J

Use the keys to increment
the Gain Number by one

and then press the ENTER
Key. Record the TOF Value.

Repeat this step for each
Gain Number.

GAIN TRAN

*01 (0 - 31)


- Or, for reflective media:

GAIN REFL

*01 (0 – 31)

Where ‘yyy’ represents the
current sensor reading.

Sample Calibration Table

Gain Number

Label Value

TOF Value

Difference Value

00 252 248
01 250 245
02 248 234

… … …

31 09 14

(Continued)